Click Here to Contact our Wakefield or Gloucester Office
Click here
 

Gas Clean-Up and Filtration Plant

You are here: Home : Products : Gas Clean-Up System

Gas Clean Up System
The main components of the gas clean-up plant are as follows:
  • Heat Exchanger with dry cooler
  • Spark arrestor
  • Bag Filter
  • ID Fan
  • Mercury & Dioxin Filter

Heat Exchanger

The heat exchnager is a double pass water jacket boiler designed to cool the exhaust gasses from the cremator to 150°C.  The closed loop design includes a dry cooler within the system.  the heat exchanger supplied with an automatic cleaning system which lowers the maintenance interval to only twice a year.

Spark Arrestor

The spark arrestor removes large particulate matter generally > 1 micron from the flue gasses to protect the bag filter.

Bag Filter

The flue gasses, already cooled to 140°C, enter the bag unit, which consists of a number of cartridge filters to remove substantially all of the remaining particulate matter.  it should be noted that this particulate matter collected in the filter unit is produced entirely from the cremation process and completely free of additives of any kind and such it does not require special treatment for disposal.


      
                                                                                                                    
Control Systems | DFW Europe Ash Processor | DFW 6000 Cremator | DFW 8000 Cremator | Gas Clean Up Systems
Copyright 2007 by WSI